Measuring junction temperature using semiconductor junction voltage drop

Semiconductor junctions (from millions of transistors in an IC to large-area composite junctions that implement high-brightness LEDs) can fail early due to the heat that is constantly being generated. This becomes a very serious problem when the feature size is reduced and the current demand is increased, and even normal operation may accumulate heat and increase the junction temperature. An increase in temperature may increase the number of defects in the junction, resulting in reduced performance and reduced life cycle of the device.

Therefore, there is a need for an accurate temperature measurement method to measure the temperature of a semiconductor device to avoid high temperatures that may cause malfunction. One method is simple: measure the junction temperature. It can use common test and measurement instruments, and measurement results can be used to monitor the operation of a particular device. The ideal way to measure junction temperature is to monitor the component temperature as close as possible to the heat source. The current flowing through the semiconductor junction generates heat that flows through the junction material to the outside world.

Another method is to place the temperature sensor very close to the semiconductor junction and measure the output signal of the sensor. As the heat flows to the outer area, the temperature of the outer area and the sensor rises. Although this is a very straightforward process, this method has many physical limitations due to the limited size of the sensor. In many cases, the sensor itself is larger than the size of the node to be measured, which adds a lot of heat to the system and introduces additional measurement errors, which reduces measurement accuracy. Therefore, this method is useless for most applications.

Figure 1: In the test setup, the SMU is used to describe the relationship between the forward voltage drop of the semiconductor and the junction temperature.

A better solution is to use the node itself as a temperature sensor. For most materials, there is a close correlation between the junction forward voltage drop and the junction temperature. When the junction forward voltage drop is nonlinear with the junction temperature depends on the material and design of the junction. In normal operating environments with temperatures up to 80 ° C to 100 ° C, it is safe to assume that the junction forward voltage drop and junction temperature of most materials are linear. The nonlinear characteristics can be determined experimentally by measuring the voltage at higher ambient temperatures until the junction forward voltage drop and the junction temperature are non-linear. For most devices, this relationship is close to a linear relationship and can be expressed mathematically as follows:

TJ=(m&TImes;VF)+T0 (1)

Where TJ = junction temperature (unit: °C); m = slope (parameters related to the device, unit: °C / V); VF = forward voltage drop; T0 = intercept (device-related parameters, Unit: °C).

Therefore, at a given temperature (TJ), the forward voltage drop (VF) of the semiconductor junction is constant. If we measure VF at two different temperatures, we can calculate the slope (m) and intercept (T0) of a node. Since this is a linear relationship, we only need to measure VF to calculate the junction temperature in different states using equation (1).

If we know the TJ of different operating states and packaged devices, we can calculate the thermal parameters of different package types and designs, such as thermal resistance. This is especially important when designing specific operating conditions to ensure the longest device life, as thermal effects are the primary cause of early device failure.

Figure 2: The four-wire measurement method reduces the error caused by the pin resistance.

Introduction

SCOTECH manufactures a full range of three phase distribution transformers, they can be oil immersed or dry type, equipped with or without oil conservator, hermetically sealed or free breathing, with corrugated tank or equipped with radiators. The three phase Distribution Transformer are widely used in power system.

 

Scope of supply

Primary voltage up to 35KV

Rated power: small size up to 315KVA, medium size up to 2500KVA, large size up to 25MVA

Installation: free standing, pole mounted, pad mounted type


 

Standards

SCOTECH`s three phase distribution transformers are designed and manufactured in accordance with all major international standards (IEC, ANSI, UL, etc.) 


Why SCOTECH

Long history- Focus on transformer manufacturing since 1934.

Technical support – 134 engineers stand by for you 24/7.

Manufacturing-advanced production and testing equipment, strict QA system.

Perfect service-The complete customer service package (from quotation to energization).


Three Phase Distribution Transformer

3 Phase Transformer,Three Phase Transformer,Three Phase Distribution Transformer,Three Phase Pole Mounted Transformer

Jiangshan Scotech Electrical Co.,Ltd , https://www.scotech.com